EPPIC Systems, LLC
Environmental Power Paper Industrial Control Systems
Mercury Reduction System
PSEG-Bridgeport, CT- 400 MW
Controls addition for new baghouse and ash removal system. DCS design, commissioning and checkout/startup.
Completion Winter 2008
Scope of Work (ABB Harmony/S800)
- DCS database
- Logic Diagrams
- DCS graphics
- Wiring and Loop Drawings
- Commissioning and start-up of carbon injection, baghouse and ash storage/removal systems
- Controls for new booster fans
- Modifications to plant's existing combustion controls
- Connection of new processors into existing plant DCS
- Ongoing support
Solid Fuel Experience
Springerville Unit 1 & Common Facilities - 400 MW CE Tangential Coal Fired Drum Unit
Controls modernization from original scope definition, budget/cash flow projection, scheduling, detail design, construction monitoring, outage planning, checkout/startup.
Completion Spring 2005
Scope of Work (DCS Foxboro IA)
- Replace Baghouse controls (TI PLC)- Unit off line
- Replace Dry Scrubber controls (Forney/Honeywell)- Unit off line
- Replace Slaker Controls -Unit off line
- Addition of New Dry Scrubber module controls unit off line
- Replace Bottom Ash controls (Relay system) Unit on line
- Replace Fly Ash controls (Relay system) Unit on line
- Replace Coal Stackout controls (Forney AFS 1000) Unit on line
- Replace Coal Reclaim controls (Forney AFS 1000) Unit on line Replace Coal Silo Fill system (Forney AFS 1000)- Unit on line Replace Turbine Controls (BBC Turbine) 6 week outage
- Replace Boiler Controls (L&N 6 Mill CE Boiler) 6 week outage
- Replace Burner Management System (CE FSSS) including new scanners - 6 week outage
- Replace Soot Blower controls (Copes Vulcan) 6 week outage
- Replace Cooling Tower controls (Forney AFS1000) 6 week outage
- Replace Integrated logic system (Forney AFS 1000) 6 week outage
- Replace data acquisition System (Westinghouse P2500) 6 week outage
- Replace Annunciator (Ronan) 6 week outage
- Replace Sequence of Events (Rochester) 6 week outage
- Replace AVR (BBC) 6 week outage
Springerville Unit 2 - 400 MW CE Tangential Coal Fired Drum Unit
Controls modernization from original scope definition, budget/cash flow projection, scheduling, detail design, construction monitoring, outage planning, checkout/startup
Completion Fall 2005
Scope of Work (DCS Foxboro IA)
- Replace Baghouse controls (TI PLC)- Unit off line
- Replace Dry Scrubber controls (Forney/Honeywell)- Unit off line
- Replace Slaker Controls -Unit off line
- Addition of New Dry Scrubber module controls unit off line
- Replace Bottom Ash controls (Relay system) Unit on line
- Replace Fly Ash controls (Relay system) Unit on line
- Replace Boiler Controls (L&N 6 Mill CE Boiler) 6 week outage
- Replace Burner Management System (CE FSSS) including new scanners - 6 week outage
- Replace Soot Blower controls (Copes Vulcan) 6 week outage
- Replace Cooling Tower controls (Forney AFS1000) 6 week outage
- Replace Integrated logic system (Forney AFS 1000) 6 week outage
- Replace data acquisition System (Westinghouse P2500) 6 week outage
- Replace Annunciator (Ronan) 6 week outage
- Replace Sequence of Events (Rochester) 6 week outage
- Replace AVR (BBC) 6 week outage
Sundt Unit 4 & Common Facilities - 165 MW FW front Fired Coal/Gas Fired Drum Unit
Controls modernization from original scope definition, budget/cash flow projection, scheduling, detail design, construction management, outage planning, checkout/startup
Completion Spring 2006
Scope of Work (DCS Emerson Ovation/Modicon)
- Replace Baghouse controls (Modicon upgrade)- 4 week outage
- Replace Bottom Ash controls (Modicon replacement) Unit on line
- Replace Fly Ash controls (Modicon replacement) Unit on line
- Replace Coal Rotary Car Dumper controls (Modicon replacement) Unit on line
- Replace Coal Stackout controls (Modicon replacement) Unit on line
- Replace Coal Reclaim controls (Modicon replacement) 4 week outage
- Replace Coal Silo Fill system (Modicon replacement)- 4 week outage
- Replace Boiler Controls (Bailey N90 3 Mill FW Boiler) 4 week outage
- Replace Burner Management System (Forney FSSS) - 4 week outage
- Replace Soot Blower Controls (Diamond Power) 4 week outage
- Replace BTG board and hardwired logic system 4 week outage
- Replace boiler thermocouple monitoring system 4 week outage
- Replace Annunciator/SOE (Hathaway) 4 week outage
- Replace UPS 4 week outage
- Replace AVR (Basler) 4 week outage
- Replace Protective relays -4 week outage
- Upgrade Chemical feed system 4 week outage
- Replace all pneumatic drives with electric drives 4 week outage
- Replace all pneumatic valve positioners 4 week outage
- Replace Electro Pneumatic Relief valve 4 week outage
- Replace all Feedwater Heater Level controls 4 week outage
System Application/Modernization Expertise
- Boiler Control Systems Turbine Control Systems
- Burner Management Systems (FSSS)
- FGD Systems (Wet & Dry)
- Lime/Limestone Preparation Systems
- Integrated Logic Systems
- Baghouse Control Systems
- Precipitator Control Systems
- Bottom Ash Control Systems
- Fly Ash Collection & Transport Systems
- Fly Ash Unloading Systems
- Coal Unloading Systems (Rotary Car Dumper)
- Coal Stackout Systems
- Coal Reclaim Systems
- Data Acquisition Systems
- Annunciator/ Sequence of Events Systems
- AVR (Automatic Voltage Regulator Systems)
- Water Treatment (Demin/RO Control Systems
- Steam &Water Quality Monitoring Systems
- CEMS
FGD Experience
- Springerville Unit 1 & 2 -400 MW (each) Joy/Niro Dry Scrubber
- Sandow Unit 4 -550 MW CE Wet Scrubber
- Forrest Grove Unit 1 & 2-750 MW B&W Wet Scrubber
- Monticello Unit 3 -750 MW Chemico Wet Scrubber
- Martin Lake Unit 1-3 -750 MW Research Cottrel Wet Scrubber